Chemical

Pentair Shaft Seal for C/EQ Series

071725S
$63.71
Replacement Pump Seals Seal Installation Guide - Installation Instructions For Replacement Seals 1. Disassemble pump cavity to expose defective seal. Removal of old seal and assembly of new seal requires careful operations and precautions. CAUTION: Lapped and polished faces of new seal are easily scratched and damaged. Protect from damage, dirt and finger prints. 2. Carefully remove old seal head and seat taking care not to scratch shaft or seat counterbore. Note how old seal is assembled, to be sure replacement seal is installed in identical manner. 3. Clean shaft and counterbore surfaces using fine emery cloth or equivalent. Remove rust, burrs and wipe clean. 4. Shaft, seat counterbore and rubber members of seal head and seat should be lubricated with a lubricant compatible with the seal elastomer. Check seal surfaces to be sure they are free of any dirt, grit or lubricants. 5. Press seal seat firmly into counterbore to be sure it is bottomed square. Slide seal head along shaft making sure that spring is correctly engaged into seal. 6. Re-assemble pump and remember that trouble free operation of a pump includes making a correct seal installation.

Need help ordering? We’re here for you.